Author Affiliations
Abstract
1 Department of Modern Mechanics, University of Science and Technology of China, Hefei 230026, China
2 Deep Space Exploration Laboratory, Hefei 230026, China
3 Laser Fusion Research Center, China Academy of Engineering Physics, Mianyang 621900, China
4 Institute of Applied Physics and Computational Mathematics, Beijing 100094, China
5 Department of Plasma Physics and Fusion Engineering, University of Science and Technology of China, Hefei, Anhui 230026, China
6 Collaborative Innovation Center of IFSA (CICIFSA), Shanghai Jiao Tong University, Shanghai 200240, China
7 CAS Center for Excellence in Ultra-intense Laser Science, Shanghai 201800, China
The evolution of ablative Rayleigh–Taylor instability (ARTI) induced by single-mode stationary and time-varying perturbations in heat flux is studied numerically in two dimensions. Compared with the stationary case, time-varying heat-flux perturbation mitigates ARTI growth because of the enhanced thermal smoothing induced by the wave-like traveling heat flux. A resonance is found to form when the phase velocity of the heat-flux perturbation matches the average sound speed in the ablation region. In the resonant regime, the coherent density and temperature fluctuations enhance the electron thermal conduction in the ablation region and lead to larger ablation pressure and effective acceleration, which consequently yield higher linear growth rate and saturated bubble velocity. The enhanced effective acceleration offers increased implosion velocity but can also compromise the integrity of inertial confinement fusion shells by causing faster ARTI growth.
Matter and Radiation at Extremes
2024, 9(1): 016603
作者单位
摘要
中国工程物理研究院 激光聚变研究中心,四川 绵阳 621900
介绍了在大型激光装置上进行 扩展X射线吸收精细结构(EXAFS)谱压缩物态参数测量的基本原理,以及为获得高质量EXAFS谱在神光III原型装置上进行的实验研究。实验采用玻璃靶球、CH靶丸和金球作为EXAFS谱测量的背光源,通过多发次叠加、光子数累积的方法获得了信噪比良好的金属Ti在常温常压下的EXAFS谱,数据处理结果表明,实验测得的金属Ti EXAFS谱拟合结果与同步辐射实验拟合结果相吻合,表明实验设计的正确性与可靠性。对实验结果的分析表明,影响EXAFS谱质量的因素主要是光子计数、测量系统谱分辨率、噪声以及实验器件上的瑕疵。
扩展X射线吸收精细结构 X射线源 大型激光装置 压缩物态 SGIII原型 EXAFS X-ray source laser facility compression SG-III prototype 
强激光与粒子束
2020, 32(5): 052002
作者单位
摘要
1 中国工程物理研究院激光聚变研究中心, 四川 绵阳 621900
2 清华大学工程物理系, 北京 100084
3 北京应用物理与计算数学研究所, 北京 100094
X射线荧光成像技术具有局域探测能力,适合诊断复杂几何构型流体运动,在实验室天体物理、惯性约束聚变等高能量密度物理领域具有重要的应用前景。基于神光Ⅲ原型激光装置,开展了X射线荧光成像的原理验证实验。实验采用聚4-甲基-1-戊烯泡沫掺杂TiO2纳米颗粒为静态客体,以钒等离子体辐射为荧光泵浦源,以平晶谱仪为分光和成像设备,成功获得了钛原子K壳层荧光的一维空间分辨强度轮廓。基于荧光产生和平晶成像原理,对荧光信号强度进行了定量估算,结果表明,模拟和实测荧光强度轮廓符合较好。该工作可为X射线荧光成像技术在复杂几何构型流体实验中的应用提供参考。
X射线光学 X射线荧光成像 平晶谱仪 掺钛泡沫 高功率激光器 
光学学报
2020, 40(6): 0634001
Author Affiliations
Abstract
Laser Fusion Research Center, Chinese Academy of Engineering Physics, Mianyang, Sichuan 621900, China
Charged particle diagnostics is one of the required techniques for implosion areal density diagnostics at the SG-III facility. Several proton spectrometers are under development, and some preliminary areal density diagnostics have been carried out. The response of the key detector, CR39, to charged particles was investigated in detail. A new track profile simulation code based on a semi-empirical model was developed. The energy response of the CR39 detector was calibrated with the accelerator protons and alphas from a 241Am source. A proton spectrometer based on the filtered CR39 detector was developed, and D–D primary proton measurements were implemented. A step range filter spectrometer was developed, and preliminary areal density diagnostics was carried out. A wedged range filter spectrometer array made of Si with a higher resolution was designed and developed at the SG-III facility. A particle response simulation code by the Monte Carlo method and a spectra unfolding code were developed. The capability was evaluated in detail by simulations.
areal density diagnostics areal density diagnostics CR39 detector CR39 detector SRF proton spectrometer SRF proton spectrometer WRF proton spectrometer WRF proton spectrometer 
High Power Laser Science and Engineering
2015, 3(4): 04000001
作者单位
摘要
中国工程物理研究院 激光聚变研究中心, 四川 绵阳 621900
在神光Ⅲ主机装置上,利用已经建成的两个激光束组,开展了激光间接驱动内爆物理磨合实验,是神光Ⅲ主机装置首次出中子实验。实验采用1400 μm×2100 μm黑腔,500 μm的塑料靶丸充1 MPa的DD燃料,激光从黑腔两端55°注入。实验获得的最高中子产额为9.7×108。实验结果表明,实验黑腔的耦合效率约为50%;使用的黑腔偏长,靶丸被压缩为“薄饼形”;中子产额和激光能量正相关;中子发射峰值时刻主要依赖于烧蚀层厚度。
神光Ⅲ主机 内爆实验 中子 峰值时刻 SGⅢ facility implosion neutron Bang Time 
强激光与粒子束
2015, 27(9): 092008
作者单位
摘要
1 中国工程物理研究院 激光聚变研究中心, 四川 绵阳 621900
2 北京应用物理与计算数学研究所, 北京 100094
在神光Ⅲ原型装置上利用八路6400 J/1 ns激光注入1100 μm×1850 μm的黑腔内产生210 eV的高温辐射场,均匀辐照填充氘氘燃料的靶丸实现内爆.实验中选择高气压薄壳靶丸实现纯冲击波聚心内爆.通过闪烁体探测器、中子条纹相机等多套诊断设备获取了中子产额、聚变反应时刻等关键内爆参数.结合一维数值模拟表明,实验测量的中子产额与干净一维数值模拟计算的中子产额之比达到90%;同时通过人为破坏内爆对称性等方式表明,该设计下内爆中子产生机制集中于冲击波聚心,其内爆性能受到高维因素影响极低,从而实现了准一维内爆.
惯性约束聚变 小收缩比 内爆对称性 流体力学不稳定性 inertial confinement fusion low compression ratio implosion symmetry RT instability 
强激光与粒子束
2015, 27(8): 082007
作者单位
摘要
中国工程物理研究院 激光聚变研究中心, 四川 绵阳 621900
基于X光微点源装置,从实验角度验证了半影成像的原理.利用针孔成像,直接测量了微点源源区图像;给出了半影孔成像、半影锥成像和环孔成像原理,以及在微点源的半影成像结果和维纳滤波重建结果.从实验结果可知:半影锥成像具有与半影孔成像相同的诊断能力,两种方法的重建图像尺寸与源尺寸一致;环孔成像的诊断能力更好,重建图像的尺寸和形状更接近源图像.
微点源 半影成像 编码装置 microfocus X-ray source penumbral imaging aperture 
强激光与粒子束
2015, 27(7): 072005
作者单位
摘要
中国工程物理研究院 激光聚变研究中心, 四川 绵阳 621900
激光间接驱动惯性约束聚变利用辐射烧蚀驱动靶丸球形内爆, 在减速阶段将内爆动能转化成热斑内能, 同时压缩燃料, 达到点火条件, 实现聚变点火。根据目前认识, 影响内爆压缩过程的主要因素包括内爆对称性、燃料熵增因子、内爆速度和混合。内爆物理实验研究的目的是发展对上述影响因素的实验表征方法, 获取这些影响因素随靶设计参数的变化规律, 建立相应的实验调控能力, 最终达到不断提升内爆性能的目的。为此, 在内爆对称性方面, 开展了Bi球自发光实验, 用于研究点火脉冲前2 ns驱动不对称性; 在内爆速度方面, 开展了球面弯晶单能流线实验, 测量得到内爆速度和剩余质量随时间的变化; 在混合方面, 开展了内壳层示踪涂层内爆混合实验, 测量得到环形发光图像。为考察综合内爆性能, 在神光Ⅱ和神光Ⅲ原型装置上开展了DT内爆实验, 获得了中子产额随初始靶参数的变化规律。
惯性约束聚变 内爆 内爆对称性 流体力学不稳定性 inertial confinement fusion implosion implosion symmetry hydrodynamic instability 
强激光与粒子束
2015, 27(3): 032015
伍波 1,2苏明 1滕建 1,2张天奎 1[ ... ]洪伟 1,2,*
作者单位
摘要
1 中国工程物理研究院 激光聚变研究中心, 四川 绵阳 621900
2 等离子体物理重点实验室, 四川 绵阳 621900
基于单能质子对CR39的标定实验,利用获取的响应曲线,设计了一种内爆初级质子的直接测量方法。在内爆初级质子产额较低的情况下,该方法可获得更多的计数。对实验中的噪声信号排除做出了说明,并对其背景噪声来源进行了分析,以提高实验数据的精确性。利用标定数据,对CR39上观察到的径迹进行鉴别,确定质子径迹并测量其径迹参数,从而确定质子能量。在随机扫描的约300个显微镜视场中获得了200个质子径迹数据,并通过与标定数据比对,获得了它们各自的能量,再利用蒙特卡罗程序Geant4修正铝膜的岐离,最终确认本次内爆实验初级质子的能谱峰值应该在2.4~2.6 MeV之间,据此换算到靶丸面密度为7~8 mg/cm2,为实验结果的进一步后续分析提供了依据。
内爆压缩面密度 CR39标定 质子径迹 质子能谱下移 areal density calibration of CR39 proton track proton spectrum peak shift 
强激光与粒子束
2014, 26(12): 122002
作者单位
摘要
中国工程物理研究院 激光聚变研究中心, 四川 绵阳 621900
基于神光Ⅱ激光装置, 利用第九路激光与金属靶Pd作用产生了能谱在2.9~3.6 keV的X射线源, 其转换效率达到8%。通过多角度带通XRD测量其发射角分布, 其分布满足cos1/3θ的规律。研究结果表明, Pd X射线源具有高亮度以及能点适中的特性, 可以应用于惯性约束聚变、天体物理等前沿科学研究。
高能量密度物理 惯性约束聚变 激光等离子体 背光照相 转换效率 high energy density physics inertial confinement fusion laser plasma backlight image conversion efficiency 
强激光与粒子束
2014, 26(8): 082003

关于本站 Cookie 的使用提示

中国光学期刊网使用基于 cookie 的技术来更好地为您提供各项服务,点击此处了解我们的隐私策略。 如您需继续使用本网站,请您授权我们使用本地 cookie 来保存部分信息。
全站搜索
您最值得信赖的光电行业旗舰网络服务平台!